[DWK Life Sciences] Product Overview

CHROMATOGRAPHY

91

Specialty Columns / ULTRA-WARE®

Chromatography Sample Tubes •

ULTRA-WARE® Filtration Systems Modular system that maximizes mobile phase preparation time at the lowest possible cost.

Design allows access to the sample via a microliter syringe needle through the hole in the PTFE-lined screw cap Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements

Separate caps for performing filtration and sparging/delivery Filtration/vacuum degassing can be performed at one central location with prepared mobile phase delivered directly to HPLC stations

Graduations x Subdivisions (mL)

Part Number Capacity (mL)

Case Qty

• Filtration cap is specially designed to filter HPLC mobile phase directly into the reservoir using 47 mm membrane filters • Vacuum degassing is accomplished by closing the HI-VAC® valve on the solvent pickup adapter • Three hole cap is used to helium sparge and deliver the mobile phase to the pump system • Helium-tight seals maximize sparging efficiency • 1/4-28 fittings and adapters are supplied to allow simple, easy connection to any HPLC pump system • Supplied with filtration cap (with 40-60 micron porosity glass support frit), standard solvent pickup adapter, three hole cap, conical bottom reservoir, standard fittings kit and FEP PTFE tubing • Patent No. 5,397,467 • Recommended for most solvents used for HPLC mobile phase • Caps and solvent pickup adapter o-rings and solvent inlet filters must be changed when using tetrahydrofuran (THF) or other aggressive solutions • Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements

422570-0000

2

0-0.3 x 0.01

1

Replacement Parts

Part Number 410116-1325 774161-0013

Description

Case Qty

PTFE-Lined 13-425 Phenolic Cap PTFE-Faced Silicone Rubber Septa

1

48

Neutral Oil and Loss Columns Apparatus for the determination of total neutral oil of natural fats and oils consisting of triglycerides and unsaponifiable matter.

Reservoir Capacity (mL)

Height x Diameter (mm)

Part Number

Case Qty

Unique design of the flask allows the transfer of the weighed sample directly onto the column

953971-1003

10000

570 x 255

1

Supplied complete, as shown

• Stopcocks have PTFE plugs, and the column has a 40-60 micron porosity fritted disc • Joints are Standard Taper 19/22 except for the extension tube, which is Standard Taper 7/25 • Ref: OACS Official Method Ca9f-57, JAOCS Vol. 46, No. 5, Pages 252-255 • Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements Free fatty acids and miscellaneous non-fat substances are removed by passing the sample through a column of activated alumina. Losses are then calculated.

ULTRA-WARE® HPLC Filtration Cap Systems • Specially designed to filter HPLC mobile phase directly into the reservoir using 47 mm membrane filters

Optional conversion base allows the use of 90 mm membrane filters for large volume, preparative scale filtration or filtering mobile phase with high particulate loads Borosilicate glass and PTFE construction gives excellent chemical resistance to all HPLC mobile phases Cap body is constructed from glass-filled PTFE and is supplied with a TFE/propylene o-ring In-line filtration with solvent pickup adapter that eliminates traditional pour-and-wait filtration 1/4” PFA (perfluoroalkoxy resin) hose barb for easy connection to a vacuum source

Column ID (mm), Column Length (mm)

Solvent Reservoir Capacity (mL)

Part Number

Case Qty

427100-0000

175

19, 270

1

Replacement Parts

• Vacuum degassing is accomplished by closing the HI-VAC® valve on the solvent pickup adapter • Supplied with a filtration cap (with 40-60 micron porosity glass support frit), standard solvent pickup adapter and conical bottom reservoir • Patent No. 5,397,467 • Recommended for most solvents used for HPLC mobile phase • O-rings in the solvent pickup adapter must be changed when using tetrahydrofuran (THF) or other aggressive organic solutions • Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements

Part Number

Description

Case Qty

175mL Solvent Reservoir for Neutral Oil and Loss Column 20mL Flask for Neutral Oil and Loss Column with 19/22 Standard Taper Joints Size 19/22 Weighing Base for 20 mL Flask for Neutral Oil and Loss Column 19 x 270 mm Column for Neutral Oil and Loss Column Size 2 Straight Bore Stopcock Plug, PTFE, 11/25 Size 4 Straight Bore Stopcock Plug, PTFE, 15.2/30

427101-0000

1

427102-0000

1

427103-0000

1

427105-0000

1

821001-0002

1

Reservoir Capacity (mL)

Height x Diameter (mm)

821001-0004

1

Part Number

Case Qty

953976-1003

10000

570 x 255

1