CONCENTRATORS
117
Distilling / Recovery / Tubes
SLOW-DRY® Concentrator Tube The Slow-Dry® concentrator tube reduces the risk of concentrating a sample to dryness.
Micro Distilling Column Micro-type distilling column designed to prevent flooding while retaining residue material.
•
• •
Unique tip features an insulated air space around the constricted end of the tube, shielding the sample and providing a protective temperature buffer Secure to assembly with 675300 polyacetal clamps, not supplied Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements
569251 has hooks; 569261 does not
Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements
•
Column Length without Joint (mm), Number of Chambers
Case Qty
•
Part Number
Feature
569251-0319 569261-0319
100, 3 100, 3
Hooks
1 1
No hooks
Standard Taper Joints
Part Number
Capacity (mL)
Case Qty
570071-1025 570071-1525 570071-2525
10 15 25
19/22 19/22 19/22
1 1 1
Solvent Recovery Condenser A versatile solvent condenser designed to recover solvents escaping during evaporative concentrations. Allows users to work outside of a hood.
•
Ref: Analytical Chemistry, Vol. 47, No. 11, p. 1879, September, 1975 Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements
Tapered Style Concentrator Tube This tapered concentrator tube is for use with Kuderna-Danish and other concentrators.
•
•
May be detached from the complete assembly and stoppered for analysis or storage Secure to assembly with springs or 675300 polyacetal clamps, not supplied Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements
Standard Taper Joints
Fits Tubing ID (inches)
Part Number
Case Qty
•
547400-0000
24/40
0.375
1
•
Standard Taper Joints
Part Number
Capacity (mL)
Case Qty
Concentrator Tube These concentrator tubes are for use with Kuderna-Danish and other concentrators.
570061-0519
10
19/22
1
•
May be detached from the complete assembly and stoppered for analysis or storage Secure to assembly with 675500 Kem-Klamps™ for tubes with hooks or 675300 polyacetal Standard Taper clamps 570050 series has hooks; 570051 series does not Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements
•
Accessories
• •
Part Number
Description
Case Qty
Size 19 Polyacetyl, Standard Taper Clamp, Blue, Fits joint sizes 19/22, 19/38 Size 24 Polyacetyl, Standard Taper Clamp, Green, Fits joint sizes 24/40, 24/45
675300-0019
12
675300-0024
12
Capacity (mL) x Standard Taper Joints
Case Qty
Part Number
Feature
570050-0425 570050-1025 570050-1026 570050-1525 570050-1526 570050-2525 570050-2526 570051-0425 570051-1025 570051-1026 570051-1525 570051-1526 570051-2525 570051-2526
4 x 19/22 10 x 19/22 10 x 24/25 15 x 19/22 15 x 24/25 25 x 19/22 25 x 24/25 4 x 19/22 10 x 19/22 10 x 24/25 15 x 19/22 15 x 24/25 25 x 19/22 25 x 24/25
Hooks Hooks Hooks Hooks Hooks Hooks Hooks
1 1 1 1 1 1 1 1 1 1 1 1 1 1
No hooks No hooks No hooks No hooks No hooks No hooks No hooks
Powered by FlippingBook