CONDENSERS
123
West / FLOW-WATCHMAN™
KIMAX® West Condenser with Medium Length Joints KIMAX® one-piece sealed unit with a Standard Taper outer joint at the inlet and a Standard Taper inner joint drip tip at the outlet. Inlet end is sloped to avoid trapping condensate. • The narrow annular space of the West design provides high cooling efficiency due to the increased flow rate of the cooling medium. • Medium length Standard Taper joints • Inner tube is light-walled with a small diameter jacket to keep minimal space between jacket and tube • Hose connections accept 5/16 inch ID flexible tubing • Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements
West Condenser with Full Length Water-Cooled 24/40 Joints Condenser with water-cooled inner and outer joints to provide maximum condensing surface.
• •
Upper Standard Taper joint is jacketed
Full length 24/40 joints
• Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements
Standard Taper Joints
Part Number
Overall Height (mm) Case Qty
452750-2430
24/40
445
1
Standard Taper Joints
Part Number
Jacket Length (mm) Case Qty
18185-1420
14/20
200
1
Jacketed West Condenser Useful for refluxing and distillation assemblies. Condensate is not restricted with this design. • The narrow annular space of the West design provides high cooling efficiency due to the increased flow rate of the cooling medium • Indentations near base of jacket for support packing • 14/20 Standard Taper joints • Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements
FLOW-WATCHMAN™ Flowmeter Keep an eye on cooling water with the Kimble® Flow-Watchman™ - a device for the visual indication of liquid flow.
•
Molded of clear polycarbonate with an inert nylon indicator ball
• •
Flow indication is visible from a distance
Usable with water down to a flow range of approximately 100 mL/minute, which is adequate for even the smallest cold finger condensers The upper flow limit is in excess of 1 liter/minute
• • • •
Standard Taper Joints
Unit operates in any position
Part Number
Jacket Length (mm) Case Qty
Lightweight all-plastic construction
Requires no auxiliary support
282555-0000
14/20
80
1
Fits Tubing ID (inches)
Part Number
Max Pressure (psi) Case Qty
626250-0000
0.25
10
1
West Condenser with Full Length 24/40 Joints The narrow annular space of the West design provides high cooling efficiency due to the increased flow rate of the cooling medium.
• •
Full length 24/40 joints
Standard Taper outer joint at the top and Standard Taper inner drip joint at the bottom
• Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements
Standard Taper Joints
Part Number
Jacket Length (mm) Case Qty
452000-2410 452000-2420 452000-2430
24/40 24/40 24/40
100 200 300
1 1 1
Powered by FlippingBook