290 PIPETS
Disposable / Serological
Sterile Disposable TD Color-Coded Serological Pipets • Non-pyrogenic • Pipets have a uniform pulled tip and are clean, plugged, sterile and ready for use • Calibrated To Deliver (TD) to the tip • Provided with “negative” graduations to increase the versatility of the pipet • 72105 series is packaged in color-coded paper/plastic individual wrap and overpacked in convenient dispensing shelf packs for laboratory benches • 72102 series is packaged in a convenient recloseable canister pack containing 50 pieces sealed in a plastic bag • Designed from ASTM Specification E714 • Manufactured from 51 expansion borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class B requirements Part Number Capacity; Tolerance (mL) Graduation Inter- vals (mL) Case Qty 72100-1110 1; ± 0.03 0.1 1,000 72100-11100 1; ± 0.03 0.01 1,000 72100-21100 2; ± 0.06 0.01 500 72100-5110 5; ± 0.15 0.1 500 72100-10110 10; ± 0.30 0.1 500 72105-1110 1; ± 0.03 0.1 1,000 72105-11100 1; ± 0.03 0.01 1,000 72105-21100 2; ± 0.06 0.01 500 72105-5110 5; ± 0.15 0.1 500 72105-10110 10; ± 0.30 0.1 500 72102-11100 1; ± 0.03 0.01 500 72102-21100 2; ± 0.06 0.01 500 72102-5110 5; ± 0.15 0.1 500 72102-10110 10; ± 0.30 0.1 500
Disposable Milk or Bacteriological Plugged Sterile Pipets Calibrated to meet APHA requirements for making milk dilutions. 1.1 mL size is also used for the milk phosphatase test.
• •
Uniform pulled tip
Clean, plugged, sterile and ready for use
• Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements Part Number Capacity; Tolerance (mL) Graduation Intervals (mL)
Case Qty
72106-11 72106-22
1.1; ± 0.025 2.2; ± 0.040
0.5, 1.0, 1.1 1, 2, 2.1, 2.2
1,000
500
Non-Sterile Disposable Serological Pipets • Pipets are non-plugged and non-sterile, with a uniform pulled tip • Calibrated to deliver to the tip • Two rings near the top indicate that the small amount remaining in the tip after free delivery has ceased must be blown out and added to the main volume delivered • Blue scale with negative graduations to increase the versatility of the pipet • Manufactured to ASTM E1380 for color coding • Bulk packed in sealed plastic bags • Manufactured from 51 expansion borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class B requirements Part Number Capacity; Tolerance (mL) Graduation Intervals (mL) Case Qty 72120-1110 1; ± 0.03 0.1 1,000 72120-11100 1; ± 0.03 0.01 1,000 72120-21100 2; ± 0.06 0.01 500 72120-5110 5; ± 0.15 0.1 500 72120-10110 10; ± 0.30 0.1 500 Sterile Disposable Serological Pipets, Shorties These “Shorty” pipets are ideal for use in tissue culture work and other procedures performed under a fume hood or in other confined areas. • The pipets have “negative” graduations to increase the versatility of the pipet • Calibrated To Deliver (TD) • Packaged in color-coded, paper/plastic individual wrap for speed and accuracy in selecting the correct size • Overpacked in convenient, dispensing shelf-packs • 72110 series is packaged in a multi-pack bag so one or several can be removed without contaminating the entire pack • Manufactured from 51 expansion borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class B requirements
Sterile Wide Tip Disposable Serological Pipets These sterile, plugged, disposable pipets are excellent for transferring viscous or suspended liquids.
• • •
Calibrated To Deliver (TD)
Non-pyrogenic
Color coded
• Multi-packed in plastic bags to protect against contamination • Manufactured from 51 expansion borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class B requirements Part Number Capacity (mL) Tolerance (mL) Case Qty 72108-5110 5 ± 0.15 400 72108-10110 10 ± 0.30 400
Proper Method of Delivering Contents • Draw liquid above top graduation using bulb or equivalent device. • Use forefinger (not thumb) for level control • Wipe any drops off outside surface only • Zero meniscus at top graduation • Drain pipet with tip touching side of receiving container • After emptying pipet, wait two seconds and remove pipet tip sideways and away from vessel wall. Do not remove the tip with an upward or downward motion • Only serological type pipets require last drops to be “blown out.” Do not “blow out” volumetric (transfer) or measuring (mohr) pipets, as they are calibrated for after “touch-off” to remain.
Part Number
Capacity; Tolerance (mL)
Graduation Intervals (mL)
Case Qty
72115-11100 72115-5110 72115-10210 72115-25210 72115-50510 72110-11100 72110-5110 72110-10210 72110-25210 72110-50510
1; ± 0.04 5; ± 0.2 10; ± 0.4 25; ± 1.0 50; ± 1.5 1; ± 0.04 5; ± 0.2 10; ± 0.4 25; ± 1.0 50; ± 1.5
0.01
400 200 200 200
0.1 0.2 0.2 0.5
50
0.01
400 200 200 200
0.1 0.2 0.2 0.5
50