[DWK Life Sciences] Product Overview

TUBES

350

Blood Collection / ESR / Capillary

B Blue Color-Coded Tubes Kimble® brand blood typing tubes feature a permanent ceramic label, fused to the glass, which is easily written on with marker or pencil.

Westergren Erythrocyte Sedimentation Rate (ESR) Tubes ESR tubes measure the rate at which red blood cells settle out of plasma. Kimble® Westergren sedimentation rate tubes may be used for the standard procedure, by drawing blood in a liquid sodium citrate vacuum tube, or the modified procedure, using a saline-diluted EDTA vacuum tube. • Precision-drawn glass and accurate calibrations ensure that the results are accurate with the standard normal values • Manufactured from 90 expansion soda lime glass conforming to USP Type III requirements Part Number ID (mm) Length (mm) Case Qty 67G830SO 2.55 240 1000

• •

Pre-labeled with blood type Convenient package quantities

• Permanent blue labels placed to allow an unobstructed view of cell suspension • Manufactured from 51 expansion borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class B requirements Part Number Capacity (mL) OD x Length (mm) Case Qty 60A10BZ3 3 10 x 75 1000 60B12BZ3 5 12 x 75 1000

IIS White Color-Coded Tubes Kimble® blood typing tubes feature a permanent ceramic label, fused to the glass, which is easily written on with marker or pencil.

Sedimentation Tube Racks with Leveling Bubbles and Adjustment Screws Sedimentation tube racks hold Westergren or Wintrobe sedimentation tubes

• •

Pre-labeled with blood type Convenient package quantities

Sedimentation tube racks feature leveling bubbles and adjustment screws

• Permanent white labels placed to allow an unobstructed view of cell suspension • Manufactured from 51 expansion borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class B requirements

• Tubes are held firmly in a perpendicular position to ensure accurate readings Part Number Feature Case Qty 2212N 6-Slot 1 2215N 10-Slot 1

Part Number

Capacity (mL)

OD x Length (mm)

Case Qty

60A10BZ6 60B12BZ6

3 5

10 x 75 12 x 75

1000 1000

Melting Point Capillary KIMAX® melting point capillary tubes are used to determine the point at which a solid sample turns to liquid. • Tubes are 100 mm long when supplied with both ends open, so that approximately 90 mm will remain after sealing • Tube length insures that the open end will extend well above the bath’s surface to prevent the bath liquid from entering the tube • 34502-99 and 34507-99 have a smaller I.D. than 34500-99 and are designed from requirements contained in the United States Pharmacopeia (USP) • Packaged with 100 tubes per vial and 20 vials per case • Manufactured from 51 expansion borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class B requirements •

IS Green Color-Coded Tubes Kimble® blood typing tubes feature a permanent ceramic label, fused to the glass, which is easily written on with marker or pencil.

• •

Pre-labeled with blood type Convenient package quantities

• Permanent green labels placed to allow an unobstructed view of cell suspension • Manufactured from 51 expansion borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class B requirements Part Number Capacity (mL) OD x Length (mm) Case Qty 60A10BZ5 3 10 x 75 1000 60B12BZ5 5 12 x 75 1000

Part Number OD x Length (mm)

Feature

Case Qty

34500-99 34502-99 34505-99 34507-99

1.5-1.8 x 100 1.5-1.8 x 100 1.5-1.8 x 90 1.5-1.8 x 90

Open at both ends Open at both ends Sealed at one end Sealed at one end

2000 2000 2000 2000

Wintrobe Erythrocyte Sedimentation Rate (ESR) Tubes ESR tubes measure the rate at which red blood cells settle out of plasma.

Use with standard or modified procedure

• Precision-drawn glass and accurate calibrations ensure that results are accurate with standard normal values • Self-zeroing Wintrobe tubes (68F828SO) are filled by means of an aspirating bulb • Round-bottomed Wintrobe tubes (64FR828B-BLUE and 64FR-828-B) are filled with a 9” Pasteur pipet • Manufactured from 90 expansion soda lime glass conforming to USP Type III requirements Part Number ID (mm) Length (mm) Case Qty 64FR828B-BLUE 3 115 2000 64FR828B 3 115 2000 66F828SO 3 150 1000

Powered by