Cell Culture
56
Ordering Information DWK Life Sciences specializes in standard and customized roller apparatus units. The part numbering system below allows for the configuration of a standard system. The main components that make up a unit include the control system, the size and type of roller bottle decks and system options. There is also a table below listing the most commonly used roller apparatus. If you have any questions about custom bottle sizes, rotation speeds or standard systems do not hesitate to contact your DWK Life Sciences representative.
Example:
W
R
T
P
F
5
11
1
-
A
Control System
R2P 2.0 Advanced touch screen with remote communications and alarms
Control System Type
R - R2P 2.0 S - Standard
STANDARD Digital display
Top Mounted Ideal design for rigorous cleaning and ceiling mounted connections Bottom Mounted Ideal design for easy access and floor mounted connections
Control System Location
T - Top Mounted B - Bottom Mounted
Decks
Production (6”/152mm) Smaller spacing between decks to allow for more bottles per area Modular (7.125”/181mm) Larger spacing between decks to allow easier removal and replacement of bottles
Spacing
Plug Style
P - Production M - Modular
A - North America - 120 VAC B - Japan - 100 VAC C - Continental Europe - 230 VAC D - United Kingdom - 230 VAC F - Australia/China - 240 VAC G - Italy/Chile - 230 VAC J - India - 230 VAC
Fixed Fixed size with a single piece uprights used for production and lighter weight due to less hardware Removale Removable decks for flexible design
Deck Type
F - Fixed R - Removable
Capacity
5 Five placement areas per deck allows for use with an upright incubator 8 Eight placement areas is used for large scale production type installions
Postions per Deck
5 8
01-11: Number of Decks Modular spaced units have a maximum of 9 decks, production spaced units have a maximum of 11 decks
No. of Decks
01-11
Options
Options
Refer to page 56 for Roll-In Incubators.
0 No options included 1 Options Included Standard Roller options include belt break alarm and battery backup R2P 2.0 options include temperature monitoring and alarms (2 probes) and battery backup (Belt break alarm included in base oering) 0 1
Part Numbers and Sizing Information for Most Common Systems
Width
Depth
Height
Weight (lb / kg)
Part Number
# Positions
# Decks
(in / cm)
(in / cm)
(in / cm)
# of Bottle Positions
Control System
Bottom Drive Production Spacing WRBPR5010-A 5
1 3
31 / 79 31 / 79 31 / 79 47 / 120 30 / 76 30 / 76 30 / 76 30 / 76 30 / 76 30 / 76 30 / 76 30 / 76 31 / 79 31 / 79 47 / 120 47 / 120
25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63 25 / 63
14 / 35 26 / 65 74 / 187 74 / 187 14 /34 14 /34 29 / 74 29 / 74 57 / 145 57 / 145 71 / 179 71 / 179 75 / 190 75 / 190 75 / 190 75 / 190
52 / 24 85 / 39
5
R2P 2.0 R2P 2.0 R2P 2.0 R2P 2.0
WRBPR5030-A WRBPF5110-A WRBPF8110-A
5 5 8
15 55 88
11 11
217 / 99 360 / 167
Bottom Drive Modular Spacing WRBMR5010-A 5
1 1 3 3 7 7 9 9
70 / 32 70 / 32 112 / 51 112 / 51 196 / 89 196 / 89 238 / 108 238 / 108 250 / 113 250 / 113 350 / 159 350 / 159
5 5
R2P 2.0
WSBMR5010-A WRBMR5030-A WSBMR5030-A WRBMR5070-A WSBMR5070-A WRBMR5090-A WSBMR5090-A
5 5 5 5 5 5 5
Standard
15 15 35 35 45 45 52 52 86 86
R2P 2.0
Standard
R2P 2.0
Standard
R2P 2.0
Standard
Top Drive Production Spacing WRTPF5110-A 5
11 11 11 11
R2P 2.0
WSTPF5110-A WRTPF8110-A WSTPF8110-A
5 8 8
Standard
R2P 2.0
Standard
Powered by FlippingBook