Liquid Handling
110
Acura ® electro 926 XS / 936 / 956 Electrontic Pipettes
Micropipettes ■ Reduced shaft length and conical end improve driveability ■ Easy access to microtubes and microplates ■ Optional longer volumetric modules ■ Simple conversion by user at any time ■ Unsurpassed metrological performance and stability Macropipettes
■ Interchangeable nozzle protection filter ■ Adapters for Pasteur pipette and straw tips ■ Outstanding accuracy and precision Multichannel ■ Large selection of 8 and 12-channel models ■ Lightweight and perfect hand fitting ■ Sequential tip ejection ■ Also fits any single channel volumetric module
Ordering Information Initial package includes pipette, charging stand and accessories. Additional pipettes (alone) supplied with individual QC certificate, pipette tips samples and operating instructions.
Cat. No.
Cat. No.
Inaccuracy (E%)
Imprecision (CV%)
Initial Package Pipette Alone
Volume
Division
Min. vol.
Mid. Vol.
Max. Vol.
Min. Vol.
Mid. Vol.
Max. Vol.
Tip Style
Micropipettes Acura ® electro 926XS W870902-A W870902
0.1 - 2µL 0.5 - 10µL 0.5 - 10YµL*
0.01µL 0.05µL 0.05µL
<± 2.5 % 1) <±1.2 % 2) <± 1.2 % 2) <± 1.2 % 2) <± 1.0 % 2) <± 1.0 % 2) <± 1.0 % 2) <± 0.8 % 2) <± 1.5 % 2) <± 1.2 % 2) <± 1.0 % 2) <± 3.5 % 2) <± 1.0 % 2) <± 0.9 % 2) <± 1.0 % 2) <± 3.5 % 2) <± 1.0 % 2) <± 0.9 % 2) <± 1.0 % 2)
<± 1.2 % <± 0.8 % <± 0.8 % <± 0.6 % <± 0.6 % <± 0.6 % <± 0.6 % <± 0.5 % <± 1.0 % <± 0.8 % <± 0.7 % <± 1.5 % <± 0.9 % <± 0.7 % <± 0.8 % <± 1.5 % <± 0.9 % <± 0.7 % <± 0.8 %
<± 0.9 % <± 0.6 % <± 0.6 % <± 0.5 % <± 0.5 % <± 0.5 % <± 0.4 % <± 0.4 % <± 0.5 % <± 0.5 % <± 0.5 % <± 1.0 % <± 0.8 % <± 0.6 % <± 0.6 % <± 1.0 % <± 0.8 % <± 0.6 % <± 0.6 %
< 2.5 % 1) < 1.5 % 2) < 1.7 % 2) < 1.2 % 2) < 0.7 % 2) < 0.7 % 2) < 0.6 % 2) < 0.4 % 2) < 0.6 % 2) < 0.6 % 2) < 0.5 % 2) < 3.0 % 2) < 1.0 % 2) < 0.6 % 2) < 0.6 % 2) < 3.0 % 2) < 1.0 % 2) < 0.6 % 2) < 0.6 % 2)
< 1.5 % < 0.7 % < 0.8 % < 0.4 % < 0.3 % < 0.3 % < 0.2 % < 0.15 % < 0.3 % < 0.3 % < 0.2 % < 0.9 % < 0.6 % < 0.4 % < 0.4 % < 0.9 % < 0.6 % < 0.4 % < 0.4 %
< 0.8 % < 0.35 % < 0.4 % < 0.3 % < 0.25 % < 0.2 % < 0.15 % < 0.1 % < 0.15 % < 0.15 % < 0.15 % < 0.7 % < 0.4 % < 0.25 % < 0.25 % < 0.7 % < 0.4 % < 0.25 % < 0.25 %
10µL 10µL
W870904-A W870906-A W870908-A W870910-A W870912-A W870914-A W870916-A
W870904 W870906 W870908 W870910 W870912 W870914 W870916
200µL 200µL 200µL 200µL 200µL 1000µL
1 - 20µL
0.1µL
2.5 - 50µL 5 - 100µL 10 - 200µL 50 - 1000µL
0.25µL
0.5µL 1.0µL 5.0µL
Macropipettes Acura ® electro 936 W870918-A W870918
0.1 - 2mL 0.25 - 5mL 0.5 - 10mL
0.01mL 0.05mL 0.05mL
2mL 5mL
W870920-A W870922-A
W870920 W870922
10mL
8-Channel Pipettes Acura ® electro 956 W870924-A W870924 0.5 - 10µL
0.05µL 0.25µL
10µL
W870926-A W870928-A W870930-A
W870926 W870928 W870930
2.5 - 50µL 10 - 200µL 20 - 350µL
200µL 200µL 350µL
1.0µL 5.0µL
12-Channel Pipettes Acura ® electro 956 W870932-A W870932 0.5 - 10µL
0.05µL 0.25µL
10µL
W870934-A W870936-A
W870934 W870936 W870938
2.5 - 50µL 10 - 200µL 20 - 350µL
200µL 200µL
1.0µL 5.0µL
W870938-A 350µL Performance values obtained in Forward mode with double-distilled water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. Performance measured at: 1) 0.5 µL, 2) 10% of nominal volume * This pipette must be used with a 200µL pipette tip
Powered by FlippingBook