[DWK Life Sciences] Product Overview

Liquid Handling

140

Hand-held, self-refilling microdispenser intended for repeat distribution of microliter volumes. Carefully selected materials ensure durability and resistance to aggressive media. Instrument combines easy handling of a regular micropipette with flexibility of a repeater pipette. There is no need for plastic tips or consumables, which may represent substantial savings. Product Advantages ■ Excellent ergonomics, soft plunger activation Acura ® manual 865 Self Refilling Microdispenser Pipette

865 5 - 50µL 20 - 200µL 100 - 1000µL

■ Large volume display ■ Easy in-lab calibration ■ No need for consumables

■ Autoclavable fully assembled at 121°C/250°F ■ Versatile feeding through bottle, tubing or syringe ■ Three-year warranty

Choice of Feeding Sources Supplied with a 90cm silicone tubing, the in- strument also fits optional feeding sources:  Bottle with luer fitting  Serum bottle holder with feed needle  Female luer valve cap for syringe

Excellent Ergonomics  Instrument shape and lightweight offer most convenient pipetting com- fort. Smooth plunger activation drastically reduces hand fatigue. Convenient Dispensing  Reliable valve system ensures high performance dispensing, dose after dose. It revolves to allow selection of the best working position. Swift-set Calibration System *  Easy and precise system with integrated key and locking mechanism, making tedious procedures a thing of the past. Protective calibration seal sticker. * Socorex patented

Ordering Information - Accessories Cat. No. Description

Qty / Pack

Vial Holder*, Luer 

W835009 W835011 W835012 W835014

1 1 1

Reservoir*, 30mL, PP, Luer  Reservoir*, 30mL, PTFE, Luer 

Manifold*, 4-Channel, 20mm Spacing, Luer Lock, Stainless Steel Manifold*, 8-Channel, 9mm Spacing, Luer Lock, Stainless Steel Inlet Valve PP Cap, Female Luer (for syringe) 

1

W835016

1 1 1

W835017 W851369

Work Station 340 for 3 Pipettes

*Autoclavable

Performance and Ordering Information - Instruments Including: 90cm silicone tubing, SS blunt end cannula, female Luer inlet valve cap, Q.C. certificate and operating instructions. Inaccuracy (E%) Imprecision (CV%) Cat. No. Volume Division Min. Vol. Mid. Vol. Max. Vol. Min. Vol. Mid. Vol. Max. Vol. W835001 5 - 50µL 0.1µL < ± 5.0 % < ± 3.5 % < ± 1.5 % < 2.0 % < 1.4 % < 0.4 % W835002 20 - 200µL 0.2µL < ± 2.5 % < ± 1.8 % < ± 1.0 % < 1.5 % < 1.0 % < 0.3 % W835004 100 - 1000µL 1.0µL < ± 1.5 % < ± 1.1 % < ± 0.6 % < 0.6 % < 0.4 % < 0.2 % *Performance values obtained with double-distilled water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.

Powered by