Refrigerators, ULT Freezers 초저온냉동고
DAIHAN® Innovation of Ultra Low Temp. Freezing System Ⅰ . Double Security and Power Up - DuoFreez TM Model Ⅱ . Simple, High Efficiency and Green - UniFreez TM Model
Ⅰ . - 95 ℃ DuoFreez TM model ; Double Security & Robustness “ Independent Dual Compressor Freezing System ”
We Offer a Unique High-stability System Powered by Two Independent UniFreez TM System, Which Operates Independently. Normally, Both Compressors would Run and It can Drop The Inner Storage Chamber’s Temperature to -95 ℃ with DuoFreez TM System, in Circumstances of Unexpected Failure of One of The Compressors, The other UniFreez TM System would still Remain Working as a ‘Back-Up’ and Maintains Ultra Low Temperature of -80 ℃ . This Innovative Realizes Utmost Stability and Robustness, Which is Most Important Feature in ULT Freezer for the Customer
※ Independent SciLab® Dual Compressor Freezing System, For DuoFreez TM model
※ Typical Cascaded Compressor System, By Two Compressors
Double Security! Even If One Compressor Fails It Maintains -80 ℃ with the Other Compressor Alone.
Temp. Increase Even If One Compressor Fails Temperature increases.
Maintain -80 ℃
Maintain -80 ℃
Temp. Increase
Temp. Increase
Comp.1 Working Fail
Comp.2
Comp.1 Fail
Working Comp.2
Comp.1 Working Fail Comp.2 * Case 1 : Compressor2 Fail
Comp.1 Fail
Working Comp.2
* Case 1 : Compressor2 Fail
* Case 2 : Compressor1 Fail
* Case 2 : Compressor1 Fail
Ⅱ . - 86 ℃ UniFreez TM model ; High Efficiency “ Single Compressor Freezing System ”
Most of Ultra Low Temperature Freezers, as Shown in The Following Diagram, Have Two Compressors Which Cooperates with Each Other to Drop The Internal Temperature Down to -86 ℃ and It’s Overall Freezing Mechanism are Quite Complex. However, Our Advanced System, UniFreez TM Only Uses a Single Compressor. Although UniFreez TM Has Just The Single Set of Compressor, Capillary Tube, Condenser, Evaporator. It Ensures The Temperature to Go Down to 86 ℃ by The Help of an Advanced Compressor Control Technology and The Process of Special Refrigerants Mixing. UniFreez TM Overcomes Technical Complexity of The Typical Cascaded Double Compressor System. Simplification of Freezing Mechanism and Electricity Minimizes The Noise, Power Consumption and Operation Failures.
※ Innovated SciLab® Single Compressor Freezing System, For UniFreez TM model
※ Typical Cascaded Compressor System, By Two Compressors
Capillary
Compressor
Compressor
Compressor
Capillary
Block Condenser (Dust is not Iaid and Filter is not necessary) Low Noise, Low Power Consumption and Simple Structure for Easy Maintenance
High Temp.
Low Temp.
649
Sales : by the Nearest Distributors. International Call Center in South Korea : +82-70-50209000